Product Description
The Yamato DG-800C / DG-810C is a 445 L glassware drying oven built for the one job most labs do every single day: drying washed glassware quickly, without spotting and without contamination. It runs at room temperature +5 °C up to 70 °C — deliberately low, because glassware does not need 300 °C and a gentler cycle protects volumetric ware from losing calibration.
Air moves by natural convection through two 34 mm exhaust ports and two 30 mm intake ports — no fan, no moving parts, nothing to service.
Key Features
- Purpose-built for laboratory glassware drying, room temp. +5 °C to 70 °C
- Stainless steel chamber with water receiving plate included
- 29 steps / 30 mm pitch — load a full day of glassware at once
- Large observation window (250 × 700 mm) to check the load without opening the door
- Natural convection — no fan, nothing to maintain
- Digital PID control with fixed temperature, auto start, auto stop and quick auto stop
Technical Specifications
| Specification | DG-800C / DG-810C |
|---|---|
| Circulation method | Natural convection |
| Operating temperature range | Room temp. +5 °C to 70 °C |
| Internal capacity | 445 L |
| Internal dimensions (W × D × H) | 620 × 600 × 1195 mm |
| External dimensions (W × D × H) | 674 × 711 × 1586 mm |
| Interior material | Stainless steel |
| Heater | SUS pipe heater 1.34 kW |
| Temperature controller | PID control by microprocessor |
| Temperature setting method | Digital setting by ▲▼ key |
| Operation modes | Fixed temperature, auto stop, auto start, quick auto stop |
| Sensor | K thermocouple · overheat protection by liquid-expansion controller |
| Exhaust port | 34 mm I.D. × 2 |
| Suction port | 30 mm I.D. × 2 |
| Observation window | Standard 3 mm glass, 250 × 700 mm |
| Door | Single door with silicone rubber gasket |
| Shelf load capacity | 15 kg per shelf |
| Shelf rest positions | 29 steps / 30 mm pitch |
| Power source | AC115V (with plug) |
| Unit weight | 78 kg (172 lb) |
| Shipping weight | 340 lb |
| Manufacturer part number | DG-800C / DG-810C |
| Country of origin | China |
Safety Features
- Independent overheat protection by liquid-expansion temperature controller
- Self-diagnostic functions with alarm
- Circuit breaker with overcurrent protection
What’s Included
- 4 shelf plates / 8 brackets
- Water receiving plate (1 pc.)
- Instruction manual
- One year manufacturer warranty
Compliance
- Manufactured under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018
- US Harmonized Tariff code 8514.19.0000 · ECCN EAR99
For quotations, lead times, accessories and volume pricing, contact Pro Lab Supply.